Triangle Tube
Insufficient DHW Temperature
Triangle Tube water heater runs but hot water output is lukewarm or cooler than setpoint.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect DHW setpoint, Scaled heat exchanger reducing transfer, Faulty mixing valve stuck too cold, Gas input below specification
How to Fix / Troubleshooting
Safety: Avoid raising setpoint above safe levels to compensate for faults.
- 1. Confirm DHW setpoint: Check the control panel and ensure the DHW setpoint is high enough (e.g., 120°F / 49°C). Adjust if necessary.
- 2. Check gas supply: If other gas appliances are weak or not working, there may be a gas supply issue. Contact your gas provider.
- 3. Inspect mixing valve: If a thermostatic mixing valve is installed, verify that its setting has not been turned down. Adjust according to manufacturer instructions.
- 4. Heat exchanger scale: Long-term operation in hard water areas can scale the DHW heat exchanger. Have a technician descale the plate or tank coil using approved chemicals.
- 5. Sensor verification: Compare the displayed DHW temperature to an accurate thermometer at a nearby tap. If the display is much higher than actual, the DHW sensor may be misreading and should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Thermostatic Mixing Valve
Check Price on Amazon
We may earn a commission from links on this page.