Triangle Tube No Power / Control Not Energized

Triangle Tube water heater will not power on; display is blank and no lights are visible.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped breaker or blown fuse, Faulty service switch, Loose power wiring, Failed internal fuse on control board

How to Fix / Troubleshooting

Safety: Working on line voltage can be hazardous. If you are not comfortable, contact an electrician or technician.

  • 1. Check breaker: Locate the circuit breaker feeding the water heater and ensure it is ON. Reset if tripped.
  • 2. Verify service switch: Many installations have a local disconnect switch. Confirm it is in the ON position.
  • 3. Inspect power cord/wiring: With power off at the breaker, remove the electrical junction cover on the heater and check for loose wire nuts or burned connections.
  • 4. Internal fuse: Some Triangle Tube controls have an internal fuse. If accessible, check and replace only with the same type and rating.
  • 5. Control board failure: If proper voltage is present at the control but the display remains dead, the control board may be defective and should be replaced by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board