F.23
Vaillant Flow/Return Temperature Difference Too High (Low Circulation)

F.23 error; unit may start then quickly shut down, often with noisy operation

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked plate heat exchanger, Partially closed valves, Failing circulation pump (on primary systems), Air in system, Scaled internal waterways

How to Fix / Troubleshooting

Safety: Isolate power and gas. Allow the appliance to cool.

  • Check valves: Confirm all service valves on the heater’s primary and DHW circuits are fully open.
  • Bleed air: Bleed the pump and high points. Air can cause poor circulation and large temperature differentials.
  • Inspect pump operation (if fitted): With power restored briefly, listen and feel for pump running. If noisy, seized, or not spinning, the pump may need replacement.
  • Clean/replace plate heat exchanger: Remove the DHW plate heat exchanger and inspect for scale or sludge. Descale using an appropriate descaling solution or replace if heavily blocked.
  • Check NTCs: Compare flow and return NTC readings. A faulty sensor can falsely indicate a large temperature difference; replace any suspect NTC.
  • Reset and test: After restoring circulation, reset the fault and run the heater under load to confirm stable operation.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

DHW Plate Heat Exchanger
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements