Vaillant Overheating DHW / Temperature Control Fault

Water heater’s hot water is too hot even at low temperature setting

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty DHW NTC sensor reading too low, Stuck gas valve at high rate, PCB control fault, Incorrectly calibrated temperature knob or sensor

How to Fix / Troubleshooting

Safety: Risk of scalding. Turn the DHW temperature setting down and warn occupants. Isolate power and gas before internal checks.

  • Verify setpoint: Confirm the DHW temperature setting on the control panel is not set too high.
  • Test DHW NTC: Compare sensor readings to actual outlet temperature. Replace the NTC if it under-reads.
  • Check gas valve modulation (engineer): Ensure the gas valve reduces output correctly at low demand. Replace if stuck at high fire.
  • Check PCB: If sensors and gas valve are correct, the PCB may be miscontrolling temperature and should be replaced.
Advertisements

Repair Difficulty

Hard 4/5