Vaillant
Reduced DHW Flow / Hydraulic Restriction
Water heater’s hot water output is lower than expected (reduced flow rate)
Advertisements
Possible Causes
Blocked inlet filter, Scaled plate heat exchanger, Partially closed isolation valve, Blocked tap/shower aerators
How to Fix / Troubleshooting
Safety: Isolate water supply and relieve pressure before removing filters or pipework.
- Clean inlet filter: Remove and clean the cold water inlet filter on the appliance.
- Check isolation valves: Ensure all service valves on the cold inlet and hot outlet are fully open.
- Clean outlets: Remove and clean aerators on taps and shower heads.
- Descale plate heat exchanger: If restrictions persist, descale or replace the DHW plate heat exchanger.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
DHW Plate Heat Exchanger
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements