F13
Viessmann
Water Pressure / Low Water Fault
F13 error, unit indicates low water pressure or lack of water in system
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Insufficient system fill pressure, Faulty water pressure sensor, Blocked pressure sensing tube, Leak in primary circuit
How to Fix / Troubleshooting
Safety: Allow the unit to cool before adding water. Overfilling can cause relief valve discharge.
- Check system pressure: Read the pressure gauge on the front or underside of the unit. For most Viessmann systems, cold pressure should be around 1.0–1.5 bar.
- Top up system: Open the filling loop or integrated fill valve slowly and watch the gauge rise. Close the valve at the correct pressure.
- Bleed air: Bleed radiators or air vents in the system to remove trapped air, then recheck pressure and top up if needed.
- Inspect for leaks: Look for water around the boiler, relief valve discharge pipe, and visible pipework. Fix leaks before refilling.
- Check pressure sensor: If pressure is correct but F13 persists, the pressure sensor or its tube may be blocked or faulty. Carefully remove and clean the sensing tube, or replace the sensor as required.