F15
Viessmann Condensate Drain Fault

F15 error, unit indicates condensate or drainage problem

Advertisements

Possible Causes

Blocked condensate trap, Frozen condensate discharge pipe, Incorrectly installed condensate hose, Faulty condensate level sensor (if fitted)

How to Fix / Troubleshooting

Safety: Switch off power. Condensate is mildly acidic; wear gloves and eye protection when handling.

  • Inspect condensate trap: Locate the plastic condensate trap at the base of the heat exchanger. Remove and flush it with clean water to remove sludge and debris.
  • Check discharge pipe: Follow the condensate pipe to its termination. Ensure it is not frozen, kinked, or blocked. Thaw frozen sections gently with warm towels; do not use open flames.
  • Verify slope: Ensure the condensate pipe slopes continuously downward with no sags that can collect water.
  • Check level sensor: If your model uses a condensate level sensor, inspect and clean it according to the manual. Replace if corroded or not switching.
  • Reset and test: Reassemble the trap, restore power, and run the heater. Confirm that condensate flows freely during operation.