Viessmann Insufficient DHW Heating

Water heater produces lukewarm water only, cannot reach set temperature

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Scaled plate heat exchanger reducing heat transfer, Gas valve not reaching full modulation, Incorrect gas pressure, Partially blocked burner or injector

How to Fix / Troubleshooting

Safety: Turn off power and gas before working on gas or hydraulic components.

  • Check DHW setpoint: Confirm the DHW temperature is set high enough on the control panel.
  • Reduce flow rate: Temporarily reduce the hot water flow at the tap. If temperature increases, the heater may be undersized or restricted by scale.
  • Descale plate heat exchanger: Isolate and chemically descale the DHW plate heat exchanger to restore heat transfer.
  • Inspect burner: Clean burner ports and check for even flame distribution. Have gas pressures and valve modulation checked by a licensed technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Plate Heat Exchanger
Check Price on Amazon

We may earn a commission from links on this page.