Possible Causes

Faulty fan motor, Fan speed sensor failure, Obstructed fan impeller, Loose fan wiring connector

How to Fix / Troubleshooting

Safety first: Isolate electrical power. Do not run the appliance with covers removed.

Owner checks:

  • Listen when the unit attempts to start: if the fan does not spin up at all, note this information for the engineer.
  • Check that the flue terminal is not blocked externally.

Engineer checks:

  • Remove the front cover and visually inspect the fan assembly for signs of overheating or obstruction.
  • Test the fan for correct voltage supply from the PCB and verify tachometer/speed feedback signal.
  • Clean the fan impeller and housing; replace the fan motor if noisy, seized, or not achieving required speed.
  • Check and reseat the fan wiring connector at both the fan and PCB ends.

Because the fan is part of the combustion air system, replacement should be done by a qualified technician.