07
Vokera
Fan Speed / Fan Feedback Fault
Vokera water heater displays code 07, appliance fails to start or locks out on fan-related error
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty fan motor, Fan speed sensor failure, Obstructed fan impeller, Loose fan wiring connector
How to Fix / Troubleshooting
Safety first: Isolate electrical power. Do not run the appliance with covers removed.
Owner checks:
- Listen when the unit attempts to start: if the fan does not spin up at all, note this information for the engineer.
- Check that the flue terminal is not blocked externally.
Engineer checks:
- Remove the front cover and visually inspect the fan assembly for signs of overheating or obstruction.
- Test the fan for correct voltage supply from the PCB and verify tachometer/speed feedback signal.
- Clean the fan impeller and housing; replace the fan motor if noisy, seized, or not achieving required speed.
- Check and reseat the fan wiring connector at both the fan and PCB ends.
Because the fan is part of the combustion air system, replacement should be done by a qualified technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Flue Fan Assembly