Vokera water heater shows code 14, appliance locks out on condensate or drainage-related fault
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Isolate power before removing the condensate trap. Condensate is mildly acidic; wear gloves and eye protection.
User checks:
- In freezing weather, check the external condensate pipe for ice. If frozen, thaw gently using warm (not boiling) water and lag the pipe to prevent recurrence.
- Ensure the condensate pipe has not been physically damaged or disconnected.
Engineer steps:
- Remove and clean the condensate trap/siphon, flushing out sludge and debris.
- Verify correct pipe gradient (continuous fall to the drain) and pipe size as per Vokera instructions.
- Prime the condensate trap with clean water before refitting.
After clearing, reset the appliance and observe operation. If the fault persists, have a technician check for internal leaks or flue issues.