Possible Causes
Oversized appliance for low flow, Restricted DHW flow path, Faulty modulation control, Incorrect minimum burner setting
How to Fix / Troubleshooting
Safety first: Rapid cycling can stress components but is not usually an immediate hazard. Do not attempt internal adjustments.
User checks:
- Increase the hot water flow rate slightly to see if cycling reduces.
- Avoid using very low flow at mixers; use a more open setting and mix at the tap.
Engineer steps:
- Check for restrictions in the DHW circuit (filters, partially closed valves).
- Verify correct gas valve modulation and minimum burner setting according to Vokera specifications.
- Inspect the DHW NTC sensor for stability.
Professional adjustment of combustion and modulation parameters may be required.