No Domestic Hot Water Production (Indirect Tank)
No hot water at faucets; Weil-McLain indirect water heater tank is cold even though boiler is operating normally.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed indirect tank circulator, Faulty tank aquastat or sensor, Closed isolation valve to tank coil, Air-locked indirect loop
How to Fix / Troubleshooting
Safety first: Turn off power to the boiler before working on circulators or wiring. Hot water can cause burns; use caution.
- Check tank temperature setting: Verify the tank aquastat or boiler DHW setpoint is set high enough (typically 120–140°F). Adjust if necessary.
- Verify circulator operation: During a hot water call, the indirect tank circulator should run. Listen for motor noise and feel the piping to and from the tank coil; it should get hot.
- Inspect valves: Ensure all valves in the indirect loop are open. A closed valve will prevent flow and heating.
- Bleed air from loop: Use purge valves on the indirect circuit to remove trapped air until a steady stream of water flows.
- Replace faulty components: If the circulator does not run with power applied, or the tank sensor/aquastat does not call for heat when the tank is cold, those parts may need replacement.