Weishaupt
Insufficient Burner Output / Partial Blockage
Water heater provides lukewarm water only; cannot reach the set temperature even at low flow.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Partially blocked burner or injector, Low gas pressure to Weishaupt unit, Faulty gas valve modulation, Scaled primary or plate heat exchanger
How to Fix / Troubleshooting
Safety: Gas and combustion work must be done by qualified personnel.
- Check user settings: Confirm the DHW temperature setpoint is high enough and that any eco or power-saving mode is not limiting output.
- Reduce flow: Test with a single hot tap at moderate flow. If temperature improves, the heater may be undersized or restricted.
- Gas supply check: Ensure the gas shut-off valve is fully open and that other gas appliances do not cause pressure drops. A gas fitter should measure dynamic gas pressure at the Weishaupt inlet.
- Heat exchanger descaling: If the unit is in a hard water area, the plate or primary heat exchanger may be scaled. A technician can perform chemical descaling to restore performance.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Plate Heat Exchanger
Check Price on Amazon