F09
Whirlpool Line Voltage / Power Supply Fault

F09 error code, water heater not heating, may indicate line voltage or power supply issue

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect supply voltage, loose power connections, reversed polarity, shared circuit overloading, internal power supply failure on control board

How to Fix / Troubleshooting

Safety first: Turn OFF power at the breaker. Use a properly rated multimeter if you are qualified.

Power checks:

  • Verify the water heater is on a dedicated circuit with the correct breaker size per the rating plate.
  • Remove the junction box cover on top of the heater and inspect wire nuts and ground connections. Tighten any loose connections.
  • Measure supply voltage at the heater input (e.g., 240V for many electric models). Compare to the rating plate.
  • Check for signs of overheating or discoloration at the wiring terminals.

Corrective actions:

  • Correct any wiring errors (e.g., loose neutral, reversed hot/neutral on 120V hybrid models) according to Whirlpool wiring diagram.
  • If supply voltage is correct and wiring is sound but F09 persists, the internal power supply on the control board is likely defective and the board should be replaced.

Warning: If you are not comfortable working with 120/240V circuits, contact a licensed electrician or technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Power Wiring Harness / Electronic Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements