F19
Whirlpool T&P Monitoring Fault

F19 error code, hybrid water heater indicates T&P (temperature and pressure) sensor or switch fault (on monitored models)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty T&P sensor, wiring issue to T&P monitor, T&P valve lifting due to overpressure or overtemperature, control misinterpretation

How to Fix / Troubleshooting

Safety first: Turn OFF power and close the cold water supply. Do not cap or plug the T&P discharge line.

Inspection:

  • Inspect the T&P valve and discharge pipe for signs of recent discharge (water stains, moisture).
  • Verify the discharge line is not blocked and terminates safely.
  • If equipped with a T&P sensor or switch, inspect wiring and connections.

If the T&P valve is leaking or lifting:

  • Check system water pressure with a gauge; install or service an expansion tank if pressure is high.
  • Replace a faulty T&P valve with the correct temperature/pressure rating.

If only the sensor is faulty:

  • Replace the T&P monitoring sensor or switch per Whirlpool instructions.

Warning: Never block or disable the T&P valve. It is a critical safety device.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Temperature and Pressure Relief Valve / T&P Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements