Worcester Bosch Oversized Boiler / Poor System Design or Sensor Placement

Boiler frequently short cycles (turns on and off rapidly) when heating.

Advertisements

Possible Causes

Boiler output too high for system, Incorrect parameter settings, Faulty or poorly placed room thermostat, Blocked or missing bypass

How to Fix / Troubleshooting

Safety first: Parameter changes should be made by a competent person following the installation manual.

Engineer actions:

  • Check boiler output settings and reduce maximum CH output via parameters where possible.
  • Ensure a suitable bypass valve is installed and correctly set to maintain minimum flow.
  • Review placement and operation of the room thermostat; relocate or replace if it is affected by local heat sources.
  • Balance radiators to improve heat distribution and reduce rapid temperature rise.