A1
Worcester Bosch Condensate Drain Blocked

Boiler shows A1 and stops, often accompanied by gurgling sounds, condensate may not be draining.

Advertisements

Possible Causes

Frozen external condensate pipe, Blocked condensate trap, Sagging or incorrectly sloped condensate pipework

How to Fix / Troubleshooting

Safety first: Turn off power before working near water or condensate pipework. Do not use naked flames to thaw pipes.

User actions (safe):

  • Locate the external condensate pipe (usually white plastic) and check for freezing in cold weather.
  • Thaw a frozen pipe by pouring warm (not boiling) water over the outside of the pipe or using warm towels.
  • Once thawed, press the reset button to restart the boiler.

Engineer actions:

  • Remove and clean the condensate trap, ensuring all debris and sludge are cleared; refill with clean water.
  • Check the internal and external condensate pipework for correct fall (slope) and secure fixings; correct any sags or backfalls.
  • Insulate external condensate pipework to reduce risk of freezing.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate Trap
Check Price on Amazon