E1 218
Worcester Bosch
Fan Speed / Airflow Fault
Boiler shows E1 218 and will not fire, fan may not run or runs briefly then stops.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty fan motor, Blocked or restricted flue, Faulty fan speed sensor or wiring, Faulty control PCB fan driver
How to Fix / Troubleshooting
Safety first: Isolate electrical power and gas. Fan and flue work must be carried out by a qualified engineer.
User checks:
- Visually inspect the external flue terminal for obstructions such as leaves, plastic bags, or ice. Do not insert objects into the flue.
- Attempt a single reset after clearing any obvious obstruction.
Engineer checks:
- Verify the fan receives correct voltage from the PCB during start-up; if voltage present but fan does not run or is noisy, replace the fan assembly.
- Inspect the flue system for correct installation, slope, and any signs of crushing or water ingress; rectify as needed.
- Check the fan speed feedback (Hall sensor or tacho) wiring and signals to the PCB; repair damaged harnesses.
- If fan and wiring are sound, test/replace the main control PCB as per Worcester Bosch procedures.
Advertisements
Repair Difficulty
Professional Required