H11
Worcester Bosch Flow Switch / DHW Demand Detection Fault

Boiler shows H11, may not respond to hot water demand or may give priority issues.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty DHW flow sensor or turbine, Blocked inlet filter, Wiring fault to flow sensor

How to Fix / Troubleshooting

Safety first: Isolate power and water. Be prepared for water spillage when removing sensors.

Engineer actions:

  • Check the DHW flow sensor/turbine for free movement and clean any debris.
  • Inspect and clean the cold water inlet filter to the boiler.
  • Test the sensor output (pulse or resistance) during water flow and compare with specifications.
  • Replace the DHW flow sensor if faulty.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

DHW Flow Sensor