Err 06
AO Smith Salt Level Sensor / Brine Well Sensor Fault

Display shows “Err 06” and the unit reports a salt system problem or low salt even when salt is present.

Advertisements

Possible Causes

Failed salt level sensor, Sensor coated with salt bridges, Loose sensor wiring, Incorrect sensor installation height

How to Fix / Troubleshooting

Safety first: Disconnect power. Do not reach into the brine tank with power connected.

Inspect the salt level sensor:

  • Locate the sensor: Many AO Smith softeners use a float or electronic sensor in the brine well (the small tube inside the salt tank).
  • Remove the brine well cover: Lift off the cover and carefully pull out the float/sensor assembly.
  • Clean the sensor: Remove salt crust, sludge, or bridging from the float and shaft. Rinse with warm water until the float moves freely.
  • Check wiring: Follow the sensor cable to the control head. Ensure the connector is fully seated and not corroded.
  • Verify installation height: Confirm the sensor is installed at the correct height per the AO Smith manual; if set too high or too low, it may misread salt level.
  • Reset alarm: Restore power and clear the error or salt alarm according to the user manual, then monitor for recurrence.

If the error returns: Replace the salt level / brine well sensor assembly. If the model uses a simple float, replace the entire float kit.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Salt Level Sensor / Brine Float Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements