AO Smith Incomplete Rinse / Excess Brine Carryover

Water has a salty taste after regeneration.

Advertisements

Possible Causes

Insufficient rinse time, High brine concentration, Drain line restriction, Incorrect valve programming

How to Fix / Troubleshooting

Safety first: Unplug the unit before changing programming or inspecting the drain line.

Check drain line:

  • Ensure the drain line is not kinked, elevated too high, or partially blocked.
  • Verify that the drain line air gap or standpipe is not restricting flow.

Programming adjustments:

  • Increase the rapid rinse time slightly within AO Smith’s recommended range.
  • Verify that the salt dosage is not set excessively high for your hardness and capacity.

After adjustments, run a manual regeneration and flush several gallons of water from a softener-fed faucet before drinking.

Advertisements

Repair Difficulty

Easy 2/5
Advertisements