E06
Aqmos Regeneration Program / Control Board Fault

E06 displayed and regeneration stops prematurely

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted control program, Faulty control PCB, Power interruption during regeneration, Incorrect parameter settings

How to Fix / Troubleshooting

Safety: Switch off power at the outlet or breaker before opening the control housing.

  • Check power stability: Ensure the softener is on a stable power circuit without frequent outages. Avoid using long extension cords.
  • Reset controller: Perform a soft reset by disconnecting power for 5–10 minutes, then reconnecting. Re-enter time, hardness, and capacity settings as per Aqmos instructions.
  • Verify settings: Confirm that regeneration time, hardness, and resin volume are correctly programmed. Incorrect values can cause abnormal cycle behavior.
  • Inspect PCB: Remove the control cover and visually inspect the PCB for burnt components, corrosion, or moisture. Dry any condensation and correct sources of leaks before reassembly.
  • Test full regeneration: Start a manual regeneration and monitor each stage. If E06 recurs at the same step, the control board is likely defective and should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Control PCB