Aqmos Flow Restriction Through Softener

Softener causes low water pressure in the house during normal service

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Clogged inlet/outlet screens, Fouled resin bed, Undersized softener for flow demand, Partially closed bypass or shutoff valves

How to Fix / Troubleshooting

Safety: Turn off water and relieve pressure before removing fittings.

  • Check bypass position: Ensure the bypass is fully in service mode and not partially closed.
  • Inspect screens: Remove inlet and outlet connections and clean any mesh screens or diffusers.
  • Test in bypass: Place the unit in bypass. If pressure improves significantly, the restriction is inside the softener.
  • Backwash resin: Run a manual regeneration to backwash and reclassify the resin bed. Persistent restriction may require resin replacement or upsizing the system.