Aquabion
Brine Refill Failure
Aquabion softener does not refill the brine tank with water after regeneration.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked refill orifice, Stuck brine refill valve, Controller not energizing refill stage, Low inlet pressure
How to Fix / Troubleshooting
Safety first: Disconnect power and close valves before disassembly.
- Check water level: After a full regeneration, the brine tank should have a specific water level. If it is dry, the refill system is not working.
- Inspect refill valve: Access the brine refill valve in the Aquabion control head. Clean any debris and verify that the small refill orifice is not blocked.
- Verify controller output: During the refill stage, check if the valve is being energized (you may hear a click or feel vibration). If not, the main control board may have a failed output.
- Manual fill: As a temporary measure, manually add the correct amount of water to the brine tank to maintain softening until repairs are completed.
Warning: Do not overshoot the recommended water level; too much water reduces brine concentration.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Brine Refill Valve
Check Price on Amazon