E06
Aquabion
Temperature Sensor Error
Display shows E06 and the Aquabion softener reports abnormal water temperature or shuts down.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed temperature probe in control head, Sensor wiring harness damaged, Sensor not seated properly in well, Control board analog input failure
How to Fix / Troubleshooting
Safety first: Disconnect power before opening the control head.
- Locate the temperature sensor: On Aquabion models with temperature monitoring, the temperature probe is typically inserted into a well on the valve body or inlet manifold. Verify it is fully inserted and secured.
- Inspect wiring: Trace the temperature sensor harness from the probe to the main control board. Ensure connectors are tight and wires are not pinched or cut.
- Check sensor resistance: With the unit powered off, disconnect the sensor and measure its resistance with a multimeter. Compare the reading to the Aquabion service chart for the current water temperature. Replace the sensor if readings are out of range or open/shorted.
- Control board diagnosis: If a known-good sensor still results in E06, the main control board input circuit may be defective and require replacement.
Warning: Do not run hot water through a cold-water-only Aquabion softener; excessive temperature can permanently damage internal seals and resin.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Temperature Sensor Probe
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements