E17
AquaClean Drain Line Blockage / Backpressure Fault

E17 displayed and the unit reports a drain line restriction or high backpressure.

Advertisements

Possible Causes

Kinked drain hose, Clogged drain line, Drain line run too long or too high, Frozen drain line

How to Fix / Troubleshooting

Safety: Unplug the unit and close the inlet valve before disconnecting the drain line. Have a bucket ready for residual water.

Steps:

  • Inspect routing: Ensure the AquaClean drain line has a smooth downward slope with no sharp bends or kinks.
  • Check for clogs: Disconnect the drain line at the softener and blow through it or flush with water to confirm it is clear.
  • Verify termination: The end of the drain line should discharge into an open drain with an air gap, not submerged in standing water.
  • Shorten if needed: If the drain line is excessively long or routed above manufacturer limits, shorten or reroute it.

After clearing restrictions, reconnect the drain line, restore water and power, and run a manual regeneration to confirm E17 is resolved.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

AquaClean Drain Line (Tubing)
Check Price on Amazon

We may earn a commission from links on this page.