E19
AquaClean Bypass Position Sensor Fault

E19 displayed and the unit reports a problem with the bypass valve position sensor.

Advertisements

Possible Causes

Failed bypass position switch, Misaligned bypass handle, Broken sensor wiring, Debris preventing full travel

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing the bypass sensor or wiring.

Steps:

  • Verify handle position: Ensure the AquaClean bypass handle is fully in the "Service" or "Bypass" detent, not between positions.
  • Inspect sensor: Locate the bypass position sensor or microswitch. Check for physical damage or misalignment with the bypass mechanism.
  • Check wiring: Confirm the sensor harness is connected securely to the control board and not pinched.
  • Test switch: Use a multimeter to test continuity of the sensor in each bypass position.

Replace the AquaClean bypass position sensor if it fails continuity tests or is physically damaged.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

AquaClean Bypass Position Sensor
Check Price on Amazon

We may earn a commission from links on this page.