E06
AquaHouse
Metered Regeneration Logic Fault
E06 error and the softener regenerates at incorrect intervals or not at all based on usage.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect hardness or capacity programming, Faulty flow meter calibration, Corrupted usage data in control board, Defective AquaHouse meter cable
How to Fix / Troubleshooting
Safety first: Work with dry hands when accessing the control panel. No plumbing disassembly is usually required for this error.
Step-by-step:
- 1. Verify programming: Enter the installer menu and confirm water hardness, resin capacity, and reserve settings match your AquaHouse model and local water test results.
- 2. Reset meter data: Use the control menu to clear usage history or perform a factory reset, then reprogram all parameters.
- 3. Check meter cable: Inspect the cable from the flow meter to the PCB for damage. Wiggle the cable gently while watching the display; intermittent readings indicate a bad cable or connector.
- 4. Perform a flow test: Run water at a steady rate and compare the displayed flow to an external flow meter or timed bucket test. Large discrepancies suggest a faulty or mis-calibrated meter.
- 5. Replace components as needed: If programming is correct and wiring is intact but E06 persists, replace the AquaHouse meter cable first, then the flow sensor, and finally the main control board if necessary.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
AquaHouse Meter Cable
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements