E16
AquaHouse
Display / Interface Communication Fault
E16 error and the softener reports a communication failure between display and main board.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose ribbon cable between display and main PCB, Damaged user interface board, Corroded connectors, Firmware incompatibility between boards
How to Fix / Troubleshooting
Safety first: Disconnect power before opening the control housing. Avoid static discharge by touching a grounded metal object before handling boards.
Step-by-step:
- 1. Remove control cover: Access the display module and main PCB.
- 2. Reseat ribbon cable: Carefully unplug and replug the flat ribbon or multi-pin connector between the display and main board. Ensure it is fully seated and not reversed.
- 3. Inspect for damage: Look for bent pins, corrosion, or cracked solder joints on the connectors.
- 4. Power test: Restore power and check if E16 clears. Gently flex the cable; if the error appears intermittently, replace the cable.
- 5. Replace interface components: If reseating does not help, replace the AquaHouse user interface board first. If the problem persists, replace the main control board as well.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
AquaHouse User Interface Board
Check Price on Amazon
We may earn a commission from links on this page.