AquaHouse
Under-Regeneration / Meter Not Counting
Softener never regenerates unless manually started, even though water usage is high.
Advertisements
Possible Causes
Flow meter not registering, Meter cable disconnected, Regeneration mode set to time-clock with long interval, Incorrect capacity or hardness settings
How to Fix / Troubleshooting
Safety first: No plumbing work is needed initially.
Step-by-step:
- 1. Check regeneration mode: Ensure the AquaHouse is set to metered mode if you expect usage-based regeneration.
- 2. Confirm flow readings: Run water and verify the display shows flow and usage increments.
- 3. Inspect meter cable: Reseat the cable between the flow sensor and main board.
- 4. Adjust settings: Correct hardness and capacity so the controller calculates realistic intervals.
- 5. Replace meter if needed: If no flow is detected despite water use, replace the AquaHouse flow sensor assembly.