E13
AquaSoft
Real-Time Clock / Timer Fault
E13 error and the unit fails to enter regeneration at the programmed time.
Advertisements
Possible Causes
Failed internal clock circuit, Power interruptions without backup, Incorrect time setting, Defective backup battery (if equipped)
How to Fix / Troubleshooting
Safety first: No high-voltage work is required for basic checks.
- Set correct time: Enter the time-of-day setting on the AquaSoft control and set the correct current time and regeneration time.
- Check power stability: Ensure the softener is plugged into a non-switched outlet that is not controlled by a wall switch or timer.
- Inspect backup battery (if present): Some AquaSoft models have an internal coin-cell or rechargeable battery. Access the control board and replace the battery with the specified type if it is depleted.
- Factory reset: Perform a control reset and reprogram all settings. Monitor whether the clock keeps accurate time over 24–48 hours.
- Replace control board: If the clock continues to drift or E13 returns, the main control board's clock circuit is likely defective and should be replaced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
AquaSoft Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.