E17
AquaSoft Inlet Pressure / Sensor Fault

E17 error and the unit indicates an inlet water pressure problem.

Advertisements

Possible Causes

Low household water pressure, Clogged inlet sediment filter, Failed pressure sensor (if equipped), Partially closed inlet valve

How to Fix / Troubleshooting

Safety first: Turn off power before removing any covers. Water pressure may be present.

  • Check household pressure: Verify that other fixtures in the home have normal pressure. If not, the issue is upstream of the softener.
  • Verify inlet valve: Ensure the AquaSoft inlet valve is fully open and the bypass is in the correct position.
  • Inspect pre-filter: If a sediment filter is installed before the softener, replace the cartridge if it is clogged.
  • Check pressure sensor: On models with a pressure sensor, inspect the sensor body and wiring. Remove the sensor and check the sensing port for debris. Clean gently and reinstall.
  • Replace sensor: If E17 persists with known-good pressure, replace the AquaSoft pressure sensor.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

AquaSoft Inlet Pressure Sensor
Check Price on Amazon

We may earn a commission from links on this page.