E08
AquaUnique Meter Calibration or Programming Error

E08 displayed and unit regenerates too frequently or not at all based on usage

Advertisements

Possible Causes

Incorrect hardness setting, Incorrect resin capacity programmed, Wrong meter size selected, Corrupted control settings

How to Fix / Troubleshooting

Safety first: No internal electrical work is required for this procedure, but do not open the control housing while powered if you are not trained.

Step-by-step:

  • Confirm water hardness: Test raw water hardness with a test kit or obtain data from your water supplier.
  • Check programming: Enter the AquaUnique installer menu and verify hardness, capacity (grains or m³), reserve, and meter size match your model and water conditions.
  • Correct settings: Adjust values according to the installation manual. Save changes and exit the menu.
  • Factory reset if needed: If settings appear corrupted, perform a factory reset (if available) and reprogram from scratch.

When to call a technician: If E08 persists after correct programming, the meter input or control board may be defective and require professional diagnosis.

Advertisements

Repair Difficulty

Easy 2/5
Advertisements