E16
AquaUnique Low Pressure or Insufficient Backwash Fault

E16 displayed and unit indicates low inlet pressure or fails to regenerate properly

Advertisements

Possible Causes

Household pressure below minimum requirement, Clogged pre-filter before softener, Partially closed inlet valve, Failing well pump or pressure tank

How to Fix / Troubleshooting

Safety first: Turn off power to the well pump if you suspect pump issues. Depressurize the system slowly to avoid water hammer.

Step-by-step:

  • Measure pressure: Use a gauge to confirm that pressure at the softener is at least the minimum specified (often 20–25 psi).
  • Check inlet valve: Ensure the inlet shutoff and AquaUnique bypass valves are fully open.
  • Inspect pre-filter: If a sediment or carbon pre-filter is installed, replace the cartridge if dirty or clogged.
  • Test pump system: On well systems, verify that the pump cycles correctly and that the pressure tank is not waterlogged.

When to call a technician: If pressure remains low or fluctuates significantly, have a plumber or pump specialist correct the supply issue before further softener service.