AquaUnique
Insufficient Capacity or Under-Sized System
Water is soft at first but becomes hard before the next scheduled regeneration
Advertisements
Possible Causes
Incorrect hardness setting too low, Resin capacity set too small, Household water usage higher than programmed, Resin volume loss due to age or damage
How to Fix / Troubleshooting
Safety first: No disassembly is required for basic checks.
Step-by-step:
- Recalculate capacity: Determine daily water usage and hardness. Use the AquaUnique manual to calculate the correct capacity and regeneration frequency.
- Adjust settings: Increase hardness value or reduce capacity setting so the unit regenerates more frequently.
- Check for resin loss: If you see resin beads in faucets or drain, the resin bed may be reduced, lowering capacity. Inspect the drain and fixtures.
- Monitor performance: After adjustments, test hardness near the end of the cycle to confirm improvement.
When to call a technician: If capacity remains inadequate, you may need a larger AquaUnique softener or resin replacement.