Over-Regeneration / Oversized Safety Margin
BWT Perla regenerates too frequently, using excessive salt and water
Advertisements
Possible Causes
Raw water hardness set too high, Capacity set too low, Leak or continuous flow downstream, Flow meter misreading high consumption
How to Fix / Troubleshooting
Safety first: No disassembly is required for parameter checks.
- Verify hardness setting: Compare the programmed raw water hardness with a recent water analysis or hardness test. Reduce the setting if it is higher than actual.
- Check capacity and safety reserve: In the installer menu, adjust the capacity and safety reserve according to BWT guidelines for your household size.
- Look for leaks: Check for continuously running toilets, dripping taps, or leaks that could cause constant flow through the softener.
- Check flow meter: With all taps closed, confirm that the display shows zero flow. If not, the flow meter may be faulty and should be inspected or replaced.