E19
BWT Perla External Control Input Fault

Display shows E19 and the unit indicates an external input or contact fault (e.g., external lock, remote signal)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted or open external contact wiring, Incorrect voltage applied to dry contact input, Misconfigured external control mode, Damaged input circuit on main PCB

How to Fix / Troubleshooting

Safety first: Disconnect power and ensure any external control circuits are de-energized.

  • Identify external connections: Locate any external control terminals on the BWT Perla (e.g., for building management systems, external lock, or regeneration trigger).
  • Check wiring: Verify that only dry contacts are connected if required. Remove any external voltage sources that may have been incorrectly applied.
  • Test without external wiring: Temporarily disconnect all external control wires and power up the unit. If E19 clears, the fault lies in the external wiring or device.
  • Review configuration: In the installer menu, ensure the external control mode matches the actual wiring (e.g., normally open vs. normally closed contact).
  • Replace PCB if internal damage: If the error persists with no external wiring connected, the input circuit on the main PCB may be damaged and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements