E01
Cillit Inlet Water Supply Fault

Controller display shows E01 and the softener does not start regeneration

Advertisements

Possible Causes

Closed inlet shut‑off valve, Blocked Cillit inlet strainer, Insufficient mains water pressure, Kinked or crushed inlet hose

How to Fix / Troubleshooting

Safety first: Close the main water supply before disconnecting any hoses. If the unit is hard‑plumbed, isolate with the upstream shut‑off valves. Disconnect power before opening the control head.

  • Check inlet valve: Verify the Cillit softener’s dedicated inlet stop valve is fully open. Many installations have a small quarter‑turn ball valve before the softener—ensure the handle is parallel to the pipe.
  • Inspect inlet strainer: Most Cillit control valves (e.g. Cillit Aquadial / Cillit HS series) have a mesh strainer at the inlet port. Close inlet/outlet valves, relieve pressure via a nearby tap, then unscrew the inlet union and remove the strainer. Rinse under running water and brush off debris. Reinstall carefully, ensuring the O‑ring is seated.
  • Check pressure: Confirm mains pressure is within the range specified on the Cillit rating plate (typically 1.5–8 bar). If pressure is low, the unit may not detect flow; consult a plumber if house pressure is inadequate.
  • Inspect hoses/pipes: If flexible hoses are used, check for kinks or crushing behind the unit or cabinet. Straighten or replace damaged hoses.
  • Reset the error: Restore water and power, then follow the Cillit control panel instructions to clear E01 (usually by pressing and holding the RESET or PROGRAM key for several seconds). Run a manual regeneration and confirm normal operation.