E16
Cillit
Overpressure / Pressure Sensor Fault
E16 error and the display shows abnormal inlet pressure or protection shutdown
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Inlet pressure above Cillit maximum rating, Faulty pressure sensor (if equipped), Blocked internal pressure regulator, Sudden pressure spikes from pump
How to Fix / Troubleshooting
Safety: High water pressure can cause leaks or bursts. Do not exceed the pressure rating on the Cillit data plate.
- Measure pressure: Use a pressure gauge on a nearby tap to measure static pressure. If it exceeds the maximum allowed (often 8 bar), install or adjust a pressure reducing valve upstream of the softener.
- Check for spikes: If a well pump or booster pump is used, verify that its pressure switch is correctly adjusted and that an expansion vessel is installed if required.
- Inspect internal regulator/sensor: On models with an integrated pressure sensor or regulator, check for blockages or damage. Replace the Cillit pressure sensor module if readings are clearly incorrect compared to a mechanical gauge.
- Reset error: After correcting pressure issues, reset the controller and monitor operation for leaks or recurring errors.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Cillit pressure sensor module
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements