Err 8
Clack
Brine Refill / Flow Meter Error
Display shows “Err 8” and the system appears to overfill or underfill the brine tank.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty turbine flow meter, Blocked flow meter turbine, Incorrect meter cable connection, Control board flow sensing failure
How to Fix / Troubleshooting
Safety: Disconnect power and close the inlet valve before removing the meter.
Steps:
- Locate the meter: On Clack WS-series valves, the turbine flow meter is typically mounted on the outlet side of the valve body.
- Inspect meter cable: Ensure the meter cable is firmly connected to both the meter and the control board. Look for cuts or abrasions in the cable. Replace the Clack meter cable if damaged.
- Check turbine for blockage: Remove the meter housing according to the service manual. Inspect the turbine for iron, sand, or debris that could prevent free spinning. Clean gently with water.
- Spin test: The turbine should spin freely with a gentle puff of air or water. If it binds or wobbles, replace the Clack turbine meter assembly.
- Verify programming: Confirm that the correct meter type and capacity are programmed in the controller. Incorrect settings can cause Err 8 and improper brine refill volumes.
- Board check: If a known-good meter and cable are installed and Err 8 persists, the control board’s flow sensing circuit may be defective and require replacement.
Tip: Install a prefilter upstream if debris repeatedly clogs the meter.