E03
Crystal Quest Brine draw / injector vacuum fault

Display shows E03 and unit does not draw brine during regeneration; brine tank level does not drop.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Clogged brine injector/nozzle in Crystal Quest control valve, Blocked injector throat or screen, Air leak at brine line or brine well, Stuck or fouled brine valve assembly

How to Fix / Troubleshooting

Safety first: Unplug the softener and close the inlet valve. Bypass the unit if possible. Relieve pressure by opening a faucet.

  • Check brine line: Inspect the 3/8" brine tubing from the control valve to the brine well. Ensure it is not kinked, pinched, or disconnected. Verify the brine safety float moves freely.
  • Clean injector: Remove the injector/nozzle and throat assembly from the Crystal Quest control valve (usually under a cap labeled INJECTOR). Note orientation. Soak the injector and screen in white vinegar to dissolve iron and scale, then rinse thoroughly.
  • Inspect brine valve: Remove and inspect the brine valve assembly (if separate). Clean any debris and ensure the check ball or plunger moves freely.
  • Reassemble and test: Reinstall the injector, screen, and brine valve. Restore water and power. Manually start a regeneration and observe the brine tank: the water level should drop during brine draw. If not, replace the Crystal Quest injector kit and brine valve assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Crystal Quest injector/nozzle & throat kit
Check Price on Amazon

We may earn a commission from links on this page.