Err 06
Ecowater Europe Salt Level Sensor Fault

Display shows “Err 06” and unit does not detect salt level correctly (salt alarm even when tank is full)

Advertisements

Possible Causes

Optical or float-type salt sensor failure, Sensor cable damaged or disconnected, Heavy salt bridging preventing sensor movement, Sensor contaminated with salt sludge

How to Fix / Troubleshooting

Safety: Unplug the unit before working inside the brine tank.

  • Check for salt bridging: Open the brine tank lid. Use a broom handle or plastic rod to gently push down on the salt. If it feels hollow underneath, break up the salt bridge so it collapses into the water.
  • Inspect sensor: Locate the Ecowater salt level sensor (float or optical probe) in the brine well. Ensure it moves freely and is not buried in hardened salt.
  • Clean sensor: Remove the sensor carefully and rinse with warm water to remove salt crust and sludge. Do not use abrasive tools.
  • Check wiring: Follow the sensor cable to the control head. Reseat the connector and inspect for cuts or crushed insulation.
  • Test operation: Reinstall the sensor, restore power, and run the salt level test (if available in the menu). If Err 06 remains, replace the salt level sensor assembly.