Err 09
Ecowater Europe Temperature Sensor Fault

Display shows “Err 09” and unit indicates abnormal temperature or shuts down during very hot or cold conditions

Advertisements

Possible Causes

NTC temperature sensor open or shorted, Sensor dislodged from valve body, Wiring harness damage, Control board analog input failure

How to Fix / Troubleshooting

Safety: Disconnect power before accessing internal components.

  • Check ambient conditions: Ensure the Ecowater softener is installed within the recommended temperature range (typically 4–49°C). Extreme cold or heat can trigger protection.
  • Locate sensor: Find the NTC temperature sensor on the valve body or manifold. Verify it is firmly seated in its well or clip.
  • Inspect wiring: Follow the sensor leads to the control board. Look for cuts, abrasions, or loose connectors. Reseat the plug.
  • Measure resistance: With power off, disconnect the sensor and measure resistance with a multimeter. Compare to Ecowater specifications at room temperature. An open or near-zero reading indicates a failed sensor.
  • Replace sensor if needed: Install a compatible Ecowater temperature sensor and clear the error by power-cycling the unit.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ecowater NTC temperature sensor
Check Price on Amazon

We may earn a commission from links on this page.