Err 12
Ecowater Europe Low Inlet Pressure Detection

Display shows “Err 12” and unit reports low inlet pressure or fails to regenerate due to insufficient water

Advertisements

Possible Causes

Main supply pressure below Ecowater minimum, Clogged inlet filter or pre-filter, Partially closed isolation valve, Faulty pressure sensor (if equipped)

How to Fix / Troubleshooting

Safety: Do not operate the softener with extremely low pressure; it may not regenerate correctly.

  • Measure pressure: Use a pressure gauge on a nearby tap to confirm inlet pressure. Ecowater softeners typically require at least ~1.4–2 bar.
  • Check valves: Ensure the main stopcock and Ecowater bypass valves are fully open in the service position.
  • Clean pre-filters: If a sediment or carbon pre-filter is installed, replace or clean the cartridge. A clogged filter can cause low pressure.
  • Inspect inlet screen: Remove and clean any inlet screens on the Ecowater valve body.
  • Sensor check: On models with a pressure sensor, inspect the sensor and wiring. Replace if pressure is normal but Err 12 persists.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ecowater inlet filter / pressure sensor
Check Price on Amazon