Err 13
Ecowater Europe
High Inlet Pressure Protection
Display shows “Err 13” and unit indicates high inlet pressure or shuts off to protect components
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Inlet pressure above Ecowater maximum rating, Faulty or misreading pressure sensor, Thermal expansion in closed system without expansion vessel, Control board analog input fault
How to Fix / Troubleshooting
Safety: Excessive pressure can cause leaks or burst components. Address pressure issues promptly.
- Measure pressure: Attach a pressure gauge to a cold tap and record static and dynamic pressure. Compare with Ecowater specifications.
- Install pressure reducer: If pressure is consistently high, have a plumber install or adjust a pressure reducing valve upstream of the softener.
- Check expansion vessel: In closed systems with a combi boiler, ensure a properly sized expansion vessel is installed to absorb thermal expansion.
- Inspect pressure sensor: If measured pressure is normal but Err 13 appears, inspect and replace the Ecowater pressure sensor as needed.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ecowater pressure sensor / external pressure reducing valve
Check Price on Amazon