Err 18
Ecowater Europe
Resin Bed Quality Sensor Fault
Display shows “Err 18” and unit indicates resin sensor or quality sensor error (advanced models)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Sensor fouled by iron or manganese, Sensor cable damaged, Sensor out of calibration, Control board sensor input failure
How to Fix / Troubleshooting
Safety: Depressurize the system before removing any in-line sensors.
- Clean sensor: Remove the resin quality sensor from its port and soak in a mild cleaning solution suitable for iron/manganese removal. Rinse thoroughly.
- Inspect cable: Check the sensor cable for cuts or crushed sections. Reseat the connector at the control board.
- Recalibrate: If the model supports sensor calibration, follow the Ecowater procedure using known soft water.
- Replace if needed: If Err 18 remains after cleaning and recalibration, replace the sensor assembly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ecowater resin quality sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements