Err 19
Ecowater Europe Low Voltage / Power Supply Fault

Display shows “Err 19” and unit indicates power supply or low voltage error

Advertisements

Possible Causes

Faulty external transformer, Loose power connector, Internal power supply circuit failure, Excessive load on control board

How to Fix / Troubleshooting

Safety: Disconnect from mains before inspecting power connections.

  • Check outlet: Verify the wall outlet supplies the correct voltage using a plug-in tester or multimeter.
  • Inspect transformer: Ensure the Ecowater power adapter is the correct model and not warm or buzzing excessively. Replace if suspect.
  • Check DC connector: Confirm the low-voltage plug is fully inserted into the softener control head and not corroded.
  • Board inspection: If a known-good transformer does not clear Err 19, the internal power supply on the control board may be faulty and require board replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ecowater external power supply / main control board
Check Price on Amazon