Ecowater Europe Regeneration Scheduling / Timer Fault

Softener does not start at the programmed regeneration time

Advertisements

Possible Causes

Incorrect time-of-day setting, Regeneration mode set to demand-only with low usage, Vacation mode enabled, Control board timer failure

How to Fix / Troubleshooting

Safety: Programming changes should be made according to the user manual.

  • Check current time: Verify the Ecowater display shows the correct time and day.
  • Review regeneration mode: Confirm whether the unit is set to time-clock, demand-initiated, or a hybrid mode. Adjust if necessary.
  • Check vacation/override: Ensure no vacation or regeneration lockout mode is active.
  • Manual regeneration: Start a manual regeneration to confirm the mechanical parts operate. If manual works but scheduled does not, the control board timer circuit may be faulty.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ecowater main control board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements