Err 06
EcoWater Metering / Flow Calculation Error

Display shows “Err 06” and the unit will not initiate regeneration based on water usage.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect meter type programmed, Flow sensor miswired, Control board firmware mismatch, Turbine miscounting due to partial blockage

How to Fix / Troubleshooting

Safety first: Unplug the unit before opening the control panel. Close bypass valves if you will open any wet components.

Steps to resolve:

  • 1. Verify programming: Enter the installer menu (refer to EcoWater manual) and confirm that the correct meter type and capacity are programmed for your model. Correct any mismatched settings.
  • 2. Inspect flow sensor wiring: Remove the cover and trace the flow sensor wires from the turbine to the control board. Ensure they are connected to the correct terminals and not reversed or loose.
  • 3. Clean turbine: If Err 06 appears intermittently, remove and clean the turbine/flow sensor assembly to ensure it spins freely and is not partially obstructed.
  • 4. Firmware compatibility: If the control board was recently replaced, confirm that the board part number is compatible with your valve and meter assembly. Incompatible firmware can cause metering errors.
  • 5. Replace faulty components: If wiring and programming are correct and cleaning does not help, replace the EcoWater turbine/flow sensor or the main control board as indicated by diagnostic tests.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

EcoWater Turbine / Flow Sensor Assembly
Check Price on Amazon