Err 08
EcoWater Stuck Relay or Output Driver Fault

Display shows “Err 08” and the unit appears to be stuck in regeneration or service mode.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Control board relay stuck closed, Shorted output transistor, Internal board contamination or corrosion, Incorrect wiring to motor or valve coils

How to Fix / Troubleshooting

Safety first: Unplug the softener before touching any internal electronics. Do not attempt board-level solder repairs unless you are qualified.

Steps to diagnose:

  • 1. Power reset: Unplug the transformer for 5–10 minutes, then plug back in. If the valve immediately moves or the error reappears, suspect a stuck relay or driver.
  • 2. Inspect for corrosion: Remove the control board and inspect both sides for white or green corrosion, burnt spots, or insect damage. If present, the board should be replaced.
  • 3. Check motor/coil wiring: Verify that the drive motor and any valve coils are wired to the correct terminals and that no wires are shorted together.
  • 4. Replace control board: If the error persists and wiring is correct, replace the EcoWater main control board. Transfer any jumpers or programming as specified in the service manual.

Because this fault involves electronic switching components, most homeowners will need an EcoWater dealer or technician to complete diagnosis and replacement.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

EcoWater Main Control Board
Check Price on Amazon